MSL-200
MSL-200 Lock
Safes with this Lock:
MFL Depository [early models]
These safes no longer come standard with this lock.

IMPORTANT
To ensure the safety of you belongings, you Must change the factory set Master Code to Your own unique code immediately!
Two Code Capacity
User Code: Factory Set
Master Code: Factory Set
Please see your user manual for the factory set Codes
or contact Tech Support.
Note:
If the safe is opened with the override code it will set the User Code back to the factory default.
WE HIGHLY RECOMMEND THAT YOU CHANGE THE DEFAULT MASTER CODE
See : How to Change the User & Override Code
IMPORTANT: PLEASE KEEP THE DOOR OPENED AND PLACE IN THE LOCKED POSITION WHEN CHANGING THE USER CODE. AFTER CHANGING THE USER CODE PLEASE TEST THE NEW CODE SEVERAL TIMES.
Wrong Code Penalty
Entry of 3 consecutive invalid codes results in a 5 minute delay period.
Audio/Visual Signals
Double signal : 2 LED flashes & 2 beeps – indicates entry is valid or accepted.
Triple signal : 3 LED flashes & 3 beeps – indicates invalid or not accepted.
Automatic Re-Locker
The controller will re-lock in 4 seconds after a valid entry is made and the door is open.
Low Battery Alert
Controller repeated beeping during an unlocking indicates that the battery is low and needs immediate replacement.
Manufacturer recommends the use of 9V Alkaline Batteries and an annual maintenance replacement of the batteries.
Single & Dual User Mode
Single Mode : Open lock with 1 code [Override or User Code]
Dual Mode : Open lock with 2 codes [User 1 & User 2 Code]
Time Delay
Time Delay : A time period waiting for opening lock. The maximum Time Delay is 99 minutes
Always Perfrom this operation with the door open
Before closing the door, make sure all the changes are correct.
Enter : #-Existing Master Code -#
The set light will stay Orange for 10 seconds
While light is still Orange :
Enter : 1-*- New Master Code -#- New Master Code -#
If a mistake is made during the change, wait 30 seconds & repeat steps 1 –
Test the new code several times before closing the door.
The lock will indicate a valid code change with a double signal; New Code has been entered.
The lock will indicate an invalid code change with a triple signal; the old code is still valid.
Note:
Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
Operations between adjacent steps need be completed in 10 seconds. Otherwise, the lock system sets back to standby status.
Enter : #- Master Code -#
The light will stay Orange for 10 seconds
While light is still Orange :
Enter : [User #] -*- New User Code -#- New User Code -#
[User #: Specify which user you would like to activate 3, 4, 5, or 6]
If a mistake is made during the change, wait 30 seconds & repeat steps 1 – 3
Example : #- Master Code -#-5-*- New User Code -#- New User Code -#
[This will activate User 5]
Test the new code several times before closing the door.
The lock will indicate a valid code change with a double signal; new code has been entered.
The lock will indicate an invalid code change with a triple signal; the old code is still valid.
Enter : #- User Code -#
The light will stay Orange for 10 seconds
While light is still Orange :
Enter : #- New User Code -#- New User Code -#
If a mistake is made during the change, wait 30 seconds & repeat steps 1 – 3
Test the new code several times before closing the door.
The lock will indicate a valid code change with a double signal; user code has been changed.
The lock will indicate an invalid code change with a triple signal; the old code is still valid.
Note:
Verify the new manager code at least 3 times before closing the door to make sure the code is correct.
Operations between adjacent steps need be completed in 10 seconds. Otherwise, the lock system sets back to standby status.
The Master and Manager can also change the user codes by following the ACTIVATE USER CODES section Steps 1 – 3.
Enter : #- Master Code or Manager Code -#
The set light will stay Orange for 10 seconds
Enter : [User #] -*-#-#
Deleting Manager Code
Enter : #- Master Code -#
The light will stay Orange for 10 seconds
The lock will indicate a valid code change with a double signal; user code has been changed.
The lock will indicate an invalid code change with a triple signal; the old code is still valid.
WARNING:
Changing the Master Code in single user mode will delete the Manager Code and all User Codes.
Changing the Master Code in dual user mode will delete the Manager Code and Users 3 & 4.
Changing the Manager Code in single user mode will delete all the User Codes.
Changing the Manager Code in dual user mode will delete Users 3 & 4.
Enter : *- User Code -#
The lock will indicate a valid code entry with a double signal & [[OPEN]] will display & light will stay Green for 5 seconds
Turn the handle clockwise before the Green light disappears.
Enter : *- User Code -#- Master Code -#
The lock will indicate a valid code entry with a double signal & [[OPEN]] will display & light will stay Green for 5 seconds
Turn the handle clockwise before the Green light disappears.
Press : * or # to initiate the Time Delay
The lock will indicate a valid setting change with a double signal.
Example: #- Master Code -#-05-#-05-# This will set a 5 minute time delay
Enter : #- Master Code -#- [01-99] -#- [01-99] -#
The lock will signal once every 10 seconds during time delay and will signal every second during the last 10 seconds of the time delay.
The lock will signal twice every 10 seconds during the open period.
[The open period length is 2 minutes]
During the open period you will need to enter your code
Enter : #- Master Code -#-00-#-00-#
The lock will indicate a valid setting change with a double signal
Enter : #- Master Code -#-0-#-0-#
The lock will indicate a valid setting change with a double signal
Enter : #- Master Code -#-2-#-2-#
The lock will indicate a valid setting change with a double signal
Please see the HOW TO OPEN YOUR SAFE section for unlocking in dual user mode.
The Green LED light will signal in Red when opening your safe.
The lock is giving you a valid signal but is not unlocking.
Turn the keypad housing to the left [counter-clockwise] & carefully pull away from the mounting plate to expose battery compartment.
Remove the 9V Alkaline Battery & replace.
CAUTION! Hold onto battery terminal to avoid pulling wires out of housing.
Carefully position the keypad into the inserts on the mounting plate and turn keypad right [clockwise].
Ensure that there are no wires or cables trapped between the keypad and the inserts on the mounting plate. Pinched cables result in a short circuit.
Please contact Tech Support at 888.381.8514 for assistance.
Live Technical Support Available Monday – Friday 8:00am – 4:30pm [Pacific Standard Time]
Click Here to view our Mesa Safe Warranty.