MSL-100 Lock

Safes with this Lock:

MFL Depository [early models]
These safes no longer come standard with this lock.

IMPORTANT

To ensure the safety of you belongings, you Must change the factory set Master Code to Your own unique code immediately!

Two Code Capacity

User Code: Factory Set

Master Code: Factory Set
Please see your user manual for the factory set Codes or contact Tech Support.

Note:

The Master Code in Single User Mode is used as an emergency override code
[Enter * – Master Code – # and the USER CODE will be set back to the factory set default code and is also used to change user settings.


The Master Code in DUAL USER MODE is used as one of the two codes in dual user mode and is also used to change user settings.
WE HIGHLY RECOMMEND THAT YOU CHANGE THE DEFAULT MASTER CODE

Wrong Code Penalty

Entry of 3 consecutive invalid codes results in a 5 minute delay period.

Audio/Visual Signals

Double Signal : 2 flashes & 2 beeps – indicates entry is valid or accepted.

Triple Signal : 3 flashes & 3 beeps – indicates invalid or not accepted.

Automatic Re-Locker

The controller will re-lock in 4 seconds after a valid entry is made and the door is open.

Low Battery Alert

Controller repeated beeping during an unlocking indicates that the battery is low and needs immediate replacement.

Manufacturer recommends the use of 9V Alkaline Batteries and an annual maintenance replacement of the batteries.

Single & Dual User Mode

Single Mode: Open lock with 1 code [Override or User Code]

Dual Mode: Open lock with 2 codes [User 1 & User 2 code]

Time Delay

Time Delay: A time period waiting for opening lock. The maximum Time Delay is 99 minutes

Always Perfrom this operation with the door open

Before closing the door, make sure all the changes are correct.

Change Master Code [3-8 digits]

Enter : #- Existing Code -#
[[SET]] will display & the light will stay Orange for 20 seconds

Enter : New Code -#
NOTE: The Master Code & User Code can be set to a 1-12 digits

[[SET]] will display & LED is now Orange for 20 seconds

Re-Enter : New Code -#

[[OPEN]] will display & LED will signal twice confirming the code change is successful

If a mistake is made wait 25 seconds and repeat steps 1 – 6

Note:

Verify the new manager code at least 3 times before closing the door to make sure the code is correct.


Operations between adjacent steps need be completed in 10 seconds. Otherwise, the lock system sets back to standby status.

 

Enter : *- User Code -#

[[OPEN]] will display & LED will signal twice indicating a valid code.

Turn the handle clockwise while [[OPEN]] is displayed & LED is Green

Enter : *- User Code -#- Master Code -#

[[OPEN]] will display & LED will signal twice indicating valid codes

Turn the handle clockwise while [[OPEN]] is displayed & LED is Green
NOTE: Valid Code – Lock will double signal
Invalid Code – Lock will triple signal

Enter : #- Master Code -#

[[SET]] will display & LED is now Orange for 20 seconds

Enter : *- [01-99-#- [01-99-#

[[OPEN]] will display & LED will signal twice confirming that the setting change is sucessful.

Press : * or # to initiate the Time Delay

[[SET]] will display & LED will signal once every 2 seconds indicating that the lock is in the delay period

After the time delay period, a 2 minute window is given to enter code

[[SET]] will display & LED will signal twice every 4 seconds during the 2 minute window

Note:

Verify the new manager code at least 3 times before closing the door to make sure the code is correct.


Operations between adjacent steps need be completed in 10 seconds. Otherwise, the lock system sets back to standby status.

Enter : #- Master Code -#

[[SET]] will display & LED is now Orange for 20 seconds

Enter : *-00-#-00-#

[[OPEN]] will display & LED will signal twice confirming that the code setting is successful

Enter : #- Master Code -#

[[SET]] will display & LED is now Orange for 20 seconds

Enter : *-1-#-1-#

[[OPEN]] will display & LED will signal twice confirming the setting change is successful

Enter : #- Master Code -#

[[SET]] will display & LED is now Orange for 20 seconds

Enter : *-2-#-2-#

[[OPEN]] will display & LED will signal twice confirming the setting change is successful

[[OPEN]] will display & LED light turns Red during an opening indicates that the battery is low and needs immediate replacement.

Uses 4 AAA Alkaline Batteries.

If batteries are depleted and will not allow lock to open, simply follow instructions below. Lock contains a non-volatile memory, even with batteries removed the lock will retain all programming.

Turn the keypad housing to the left (counter clockwise) and carefully pull away from the mounting plate to expose battery compartment.

Remove the 4 AAA Alkaline Batteries & replace.
CAUTION! Hold onto battery terminal to avoid pulling wires out of housing.< /li>

Carefully position the keypad into the inserts on the mounting plate and turn keypad right [clockwise].
Ensure that there are no wires or cables trapped between the keypad and the inserts on the mounting plate. Pinched cables result in a short circuit.

Please contact Tech Support at 888.381.8514 for assistance.

Live Technical Support Available Monday – Friday 8:00am – 4:30pm [Pacific Standard Time]
Click Here to view our Mesa Safe Warranty.
Click Here to view our Limited Lifetime MBF Gun Safe Warranty.

Available Downloads